As we all know, optical fiber is a cable that is often used in our integrated wiring. I don't need to say more about fiber optics, and everyone knows it well. What we are going to talk about today is what specifications are there for fiber patch cord wiring! Come and see it together!
1. When only a single cabinet is placed in the computer room and there is no 0DF dedicated cabinet
When laying optical fiber patch cords, the optical fiber patch cords should exit from the optical fiber port of the photoelectric conversion card in the frame and extend downward, and pass through the upper side of the cable management device for optical fiber patch cables. : When laying the optical fiber patch cords for the chassis, the optical fiber patch cords of the photoelectric conversion card in the first card slot from left to right in the chassis should be placed in the first distribution slot from the left to the upper right side of the cable organizer. , Route the optical fiber patch cord of the photoelectric conversion card in the second card slot from left to right in the frame into the second split slot from left to upper right of the cable manager, and so on), and then connect the optical fiber patch cord The rear slot of the special cable manager for wiring is routed through the left side of the front of the cabinet, and extends upward along the left side of the front of the cabinet into the ODF terminal box (Note: If there are cable management slots on both sides of the front of the cabinet, the optical fiber should The wiring is routed in the cable management slot on the left side of the front of the cabinet), and then enters the corresponding ODF terminal box terminal disc from the ODF terminal box splitter. If there is redundancy in the length of the optical fiber patch cord, the redundant part shall be sorted out and arranged. mounted on the bottom of the cabinet.
2. When there are multiple cabinets or special cabinets for 0DF in the computer room
When there are multiple cabinets in the equipment room and there is no 0DF special cabinet, one cabinet should be designated as the 0DF special cabinet. This cabinet cannot install or place any equipment unrelated to the ODF terminal box. The ODF terminal box is only allowed to be installed in the designated Inside the ODF dedicated cabinet.
When laying out optical fiber patch cords, the optical fiber patch cords should exit from the optical fiber port of the photoelectric conversion card in the chassis and extend downwards, and pass through the cable management slot on the upper side of the special cable management device for optical fiber patch cables (Note). : When laying the optical fiber patch cords for the chassis, the optical fiber patch cords of the photoelectric conversion card in the first card slot from left to right in the chassis should be placed in the first distribution slot from the left to the upper right side of the cable organizer. , Route the optical fiber patch cord of the photoelectric conversion card in the second card slot from left to right in the frame into the second split slot from left to upper right of the cable manager, and so on), and then connect the optical fiber patch cord The rear side of the special cable manager for wiring is routed through the cabling at the front of the cabinet near the side of the ODF special cabinet, and extends upward along the front of the cabinet near the side of the ODF special cabinet (Note: If there are cable management grooves on both sides of the front of the cabinet, it should be Route the fiber patch cords in the front end of the cabinet near the cable management slot on the side of the dedicated ODF cabinet), pass through the wiring holes on the same side of the cabinet top, and pass through the top wiring holes of the cabinet. If the equipment room has a bridge, the fiber patch cords should be passed through the top of the cabinet Enter the upper bridge, and route the cables left or right on the bridge to the upper end of the top of the ODF special cabinet, then extend downward from the bridge, and pass the wiring hole on the left side of the top upper end of the ODF special cabinet into the ODF special cabinet. With a bridge frame, the optical fiber patch cords should be routed to the left or right along the top upper end of the cabinet to the left wiring hole on the top upper end of the ODF special cabinet. Wiring from the left side of the ODF special cabinet to the ODF terminal box splitter (Note: If there are cable management slots on both sides of the front of the cabinet, the fiber patch cords should be wired in the cable management slot on the left side of the front of the cabinet), and then enter the corresponding The terminal disc of the ODF terminal box. If there is redundancy in the length of the optical fiber patch cord, the redundant part shall be sorted out and placed in the special ODF cabinet.
The above is the entire content of the specifications for the wiring of optical fiber patch cords. Of course, the wiring in the computer room should not be done arbitrarily. The actual wiring of the network cable should be carried out on the spot. The cable troughs should be wired in their own dedicated cable managers or cabinet cable management slots, and the equipment power cables, network cables, and optical fiber patch cords are not allowed to be entangled with each other, and should be bundled separately from the network cables and optical fiber patch cords.